Selecting a channel bank and transferring the scan result to the receivers
The receiver that has performed the frequency preset scan will then display
(for each channel bank) the number of free frequencies (channels). The
“CHANNEL” LEDs of all receivers of this frequency range flash slowly.
Disturbed or occupied frequencies are blocked for frequency assignment.
On the receiver that has performed the frequency preset scan, select a
channel bank with a sufficient number of free channels using the /
rocker button (refer to the instructions for use of the receiver). The
selected channel bank must have (at least) as many free channels as
receivers from this frequency range are connected to the NET 1.
Confirm your selection by pressing the SET button.
The NET 1 assigns the frequencies of the selected channel bank to all
connected receivers of the frequency range. The yellow “SCAN” LED
goes off and the yellow “DATA LINK” LED flashes slowly until the
frequencies have been transferred to all receivers.
Note:
If you have connected more receivers (from one frequency range) than
free channels are available in one channel bank, the NET 1 re-assigns the
last frequency assigned to the subsequent receivers.
Transferring frequencies to the transmitters of a frequency range after a
frequency preset scan
You can transfer the frequencies to the corresponding transmitters of the
system using the infra-red interface of the NET 1 (no cable required).
The infra-red interface of the bodypack transmitters is located in the battery
compartment.
For data transfer, open the cover of the bodypack transmitter.
The infra-red interface of the hand-held transmitters and plug-on trans-
mitters is located under the display’s faceplate.
Note:
Strong extraneous light may interfere with the transfer of the
transmission frequencies via the infra-red interface. Therefore, position
the NET 1 so that any possible interference caused by extraneous light is
avoided. The arrow in the diagram on the left indicates the direction from
which the IR radiation must impinge upon the transmitter.
After the frequency preset scan, the NET 1 indicates that you can transfer the
frequencies to the transmitters as follows:
y The infra-red interface is permanently backlit in blue.
y The “CHANNEL” LEDs of all devices of one frequency range flash slowly.
y The yellow “DATA LINK” LED flashes until all frequencies have been
transferred to the transmitters.
To transfer the frequency to the transmitter, proceed as follows:
Switch on the transmitter as described in the instructions for use of the
transmitter.